Dual-Releasing Control Panel – 6-zone

Listed to UL 864, 9th edition
• Field configurable to operate with a Deluge
Sprinkler System, a Pre-action Sprinkler System
and an Agent Release System
• Six Class B (Style B) Input Circuits
• Input Circuits One to Four can be configured as
Non-Verified Alarm, Non Latching Supervisory,
Latching Supervisory or Agent Release/Water Flow
depending on the Mode of Operation selected
• Input Circuits Five & Six can be configured as
Manual Release Input, Abort Input or Abort/Manual
Release Combination Input depending on the Mode
of Operation selected
• Input Circuits can be converted to Class “A” (Style
“D”) using the ICAC-306 Converter Module
• Four Class “B” (Style “Y”) Output Circuits which can be
configured for Silenceable Signal, Non-Silenceable
Signal, Silenceable Strobe, Non-Silenceable
Strobe or Releasing Circuit (Circuits 3 & 4 Only)
• Output Circuits can be converted to Class “A” (Style
“Z”) using the OCAC-304 Converter Module
• 5 Amp Power Supply
• 4-wire smoke power 22.3 VDC @ 300ma max.
Supervised Aux Power 22.3 VDC @ 500ma max.
• Aux Power (Unregulated) 24 VDC @ 1.7 Amp max.
• Relay contacts for Common Alarm (Non
Disconnectable), Auxiliary Alarm (Disconnectable),
Common Supervisory (can be converted to common
alarm if no Supervisory input) and Common Trouble
• Cross Zone option
• Counting Zones option
• Output signals can be configured for Steady (fixed) or
Escalating (tone changes as input operation changes)
• Release Timer 0 to 60 Seconds (5 second increments)
• Manual Release Delay 0 to 30 Seconds (5 second
increments)
• Soak Timer 0 to 15 Minutes (21 Intervals)
• Abort Release Timer (Standard UL Type Delay, IRL
Type Delay, NYC Type Delay, Local Jurisdiction Delay)
• Special Releasing Power Supply and Release
Activation Considerations preventing false dumps
• Configurable to perform two hazard areas
• Simple panel programming through 14 PreConfigured
Modes of Operations